4-1
4.1 Unit properties
4 Function description
44000Function descriptionFunction description4-4.1Unit properties4100Unit properties4-
4.1.1 Integrated protection mechanisms
Integrated protection mechanisms4-
The relay conforms to the following safety criteria:
` The circuit is redundant with built-in self-monitoring.
` The safety function remains effective in the case of a component fail-
ure.
4.1.2 Function description
Function description4-
4.1.2.1 Operation
Operation4-
The speed monitor can monitor an axis for standstill, speed and direc-
tion of rotation. The speed monitor signals the status of the monitored
values to the base unit. Depending on the implemented safety circuit,
the values may be transferred from the base unit to a relay output on the
safety system, for example. Incremental encoders may be used to
record the values.
The configuration of the speed monitor is described in detail in the
PNOZmulti Configurator's online help.
4.1.2.2 Block diagram
Block diagra m4-
Interface
to previous
module
Interface
to next
module
X12
X1